Benefits of fire guard ceilings and grid.
Roof ceiling fire rated assemblies.
Meet astm e1264 class a rating.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
2 x 10 16 o c span 12 14 live load 40lbs w 3 4 wood sheathing ceiling 3 8 gwb.
2 x 8 16 o c span 12 live load 40 lbs w 3 4 t g plywood ceiling 1 2 non rated gwb.
Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system.
Concrete with cellular steel 3 hr.
Only fire guard products can be used in fire rated assemblies and are idenfified with the fire guard icon.
These assemblies need to meet fire and smoke safety and environmental sustainability requirements.
Urb concealed grid system and tile.
722 6 2 1 fire resistance rating of wood frame assemblies.
Refer to our roof ceiling assembly documents which includes ul fire rated roof assemblies for easy guidance through the assembly of a roof or ceiling on your next project.
The fire resistance rating of a wood frame assembly is equal to the sum of the time assigned to the membrane on the fire exposed side the time assigned to the framing members and the time assigned for additional contribution by other protective measures such as insulation.
Fire guard ceilings and grid systems are designed to provide enhanced resistance against structural failure.
Fire partitions must extend from the top of the floor below to the underside of the floor or roof sheathing or to the underside of the fire resistance rated floor ceiling or roof ceiling assembly above.
Have a question about assemblies.
Floor ceiling.
Roof floor ceiling time assembly ff file no.
Overview fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building.
As explained there these ratings are applied to certain types of roof ceiling and floor ceiling construction assemblies which are tested and assigned hourly ratings mandated by building codes or other building safety requirements.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
As applied to elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies.
If you are unfamiliar with ul fire resistance ratings begin with a review of meeting code requirements pg.
The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.